Problem with retract in begin procedure

Locked
krmela
Posts: 2
Joined: 10 Dec 2014, 02:09

Problem with retract in begin procedure

Post by krmela »

Small problem with retract filament in begin procedure. Retract length is always 1.5 mm regardless of the setting destring_suck/destring_prime.
User avatar
DDME-Marc
Posts: 5
Joined: 09 Nov 2014, 20:30
Location: New Zealand

Re: Problem with retract in begin procedure

Post by DDME-Marc »

Have you checked that are selecting and are adjusting the correct material from your library?

In the material name tab it should show which extruder number has been assigned to your material. Double check to see if it matches
material.jpg
material.jpg (25.38 KiB) Viewed 2152 times
Cheers,

Marc
Felix 3.0 Dual Head * E3D Titan V6 * Repetier-Host V2.0.5 * Repetier-Firmware 0.92.9 (01/08/17 - Modified) * KISSlicer Pro - 1.6.2 *
krmela
Posts: 2
Joined: 10 Dec 2014, 02:09

Re: Problem with retract in begin procedure

Post by krmela »

OK. If I change destring Prime/Suck mm on page Material, I must also manually edit Prefix Retract filament on Ptr G-code page. For example, destring 0.5 mm, retract filament in start procedure must be 29.5 mm.
Attachments
retract.png
retract.png (11.77 KiB) Viewed 2140 times